Sunday, August 17, 2014

Fuel Gauges: Do they Indicate Properly


Fuel Gauges: Do they Indicate Properly?

by Tom Bennett, Civil Aviation Safety Inspector, Aircraft Maintenance and Manufacturing, Prairie and Northern Region, Civil Aviation, Transport Canada
There have been multiple incidents of fuel exhaustion over the past few years. In the last issue of the Aviation Safety Letter (ASL), you read about fuel starvation due to improper fuel selector condition. In this article, I would like to talk about another common factor in fuel starvation incidents: fuel gauges that do not indicate properly.
Some incidents were very public, whereas most incidents went unnoticed with the exception of being listed in the Civil Aviation Daily Occurrence Reporting System (CADORS). Some incidents were directly related to poor fuel management by the flight crew(s); however a few came as a surprise to the flight crew, as the fuel gauge(s) still indicated there was fuel in the tanks. An accurate reading of the fuel gauge may have prevented many of these occurrences.
There is some confusion about the need for serviceable fuel gauges. This confusion is especially prominent in the general aviation world. As both an aircraft maintenance and manufacturing inspector and an enforcement investigator, I have heard statements like: “The gauges have never worked properly. I just keep track of time in my tanks,” many times.
Such a statement is contrary to Canadian Aviation Regulation (CAR) 605.14(j)(i), which states: “No person shall conduct a take-off in a power-driven aircraft for the purpose of a day VFR flight unless it is equipped with a means for the flight crew, when seated at the flight controls to determine the fuel quantity in each main fuel tank […]”. This regulation is then carried through in sections 605.14, 605.15, 605.16 and 605.18 of the CARs, to apply to all power-driven aircraft in all nature of flights (day/night visual flight rules [VFR]/instrument flight rules [IFR]).
Furthermore, many aircraft must have their fuel gauges working as per their type certificates. For larger aircraft, especially transport category aircraft, the fuel gauges can be deferred by means of the minimum equipment list; however, this usually involves using other measuring devices installed on the aircraft and making complex calculations.

Fuel Gauges that indicate incorrect fuel levels
A common factor in fuel starvation incidents:
fuel gauges that do not indicate properly

Recently, a commercial pilot was fined because one of his fuel gauges was not working while he was operating an aircraft. In this case, as in others, the fuel exhaustion caused substantial damage to the aircraft during the forced landing. The pilot applied to the Transportation Appeal Tribunal of Canada (TATC) to seek relief from the $750. The TATC upheld the Minister’s decision.
The Aviation Enforcement Branch has also sanctioned aircraft owners and operators for unserviceable fuel gauges found during Transport Canada’s oversight activities. The maximum sanctions for an infraction under CAR 605.14, 605.15, and 605.16 are $3,000 for an individual and $15,000 for a corporation. The maximum sanctions for an infraction under CAR 605.18 (IFR) is $5,000 for an individual and $25,000 for a corporation. Inspection, maintenance and repair of a fuel indication system seem less costly, in my opinion.
Another common excuse I hear is that the gauges have always displayed faulty readings or they are too difficult or expensive to calibrate. As an aircraft owner, if you rely on this flawed thinking you are exposing yourself to numerous risks. First and foremost, you risk running out of fuel. This can lead to personal injury/fatality and damage/loss to the aircraft. Second, you are exposed to regulatory action by enforcement (fine or suspension). I think we can all agree that none of these are pleasant outcomes.
For the aircraft maintenance engineers (AME) in this scenario, I have not yet seen an inspection where the functionality of the fuel quantity indication system is not checked. Be careful what you sign for on the inspection forms and subsequently, the maintenance release. Following manufacturers’ instructions for inspection, maintenance and repairs will never lead you astray.
Most pilots and AMEs are aware that any accident or incident results from a series of events; there is never just one cause. Anything we can to do tighten up against the possibility of an error is a step in the right direction. 


Crown Copyright and Licensing, Public Works and Government Services Canada
Crown Copyright Clearance CCL FILE # 2011-33369
(c)Transport Canada, Aviation Safety Letter Issue 1/2011

Sunday, February 23, 2014

CiES Fuel Sender - In the News - March 2014 Aviation Consumer

In the March 2014 Issue of Aviation Consumer the CiES Cirrus Fuel System Retrofit is reviewed.


As we have talked about in previous blog posts - Cirrus G1 / G2 retrofits are a challenge.  The results and review were favorable and represent what can be obtained on the early series aircraft.   Later model Cirrus G3's can achieve nearly perfect results.

Please look to 


for more information and other informative articles

Thursday, October 11, 2012

Press Release - TSO Granted - AOPA Summit


NEWS RELEASE                                    FOR IMMEDIATE RELEASE


CIES Corporation receives FAA TSO approval for new digital fuel level senders

October 10, 2012, CIES Corporation of Redmond, Oregon has received FAA TSO C55a approval for its line of digital fuel level senders. The float based fuel level senders are designed to replace the majority of the existing fuel level sending systems in general aviation aircraft. The proprietary and patented system provides a new level of accuracy, reliability, and stability to fuel level indication in the cockpit. CIES meets a TSO standard of 2% variance in tank volume, a standard normally reserved for corporate and commercial aircraft with corrected capacitive solutions. No other float based system meets this stringent TSO standard while achieving the intrinsically safe (i.e. “no wires in the tank”) requirement.

Richard Kirkness, Vice President of CIES said, "As a manufacturer of aircraft systems, we see FAA certification as critical to our success and the foundation for everything we do. FAA approval is the result of months of hard work on the part of our team here in Redmond and could not have come at a better time for CIES as the company continues to grow and strives to achieve the goal of becoming a world class supplier of advanced systems and technologies.”

Charlie Babb, General Manager of CIES added, “After the successful introduction at the beginning of this year of our senders on all new Cirrus production aircraft, we began working with other manufacturers and owners groups to provide specific fuel level sending solutions for production and legacy aircraft. The next logical step was to acquire FAA certification to validate our quality control system and lean manufacturing processes while making aircraft integration and approval significantly easier to obtain.”
The CIES fuel level senders require a dedicated digital fuel level display to ensure that the 2% accuracy achieved in the fuel tank is provided in the cockpit as well. As a result, CIES partnered with Aerospace Logic in Hamilton, Ontario to utilize their digital fuel level cockpit display. Aerospace Logic updated their fuel level gauging system to accept the digital communication link from the CIES digital senders.

CIES Corporation of Redmond, Oregon USA provides a range of high-technology products and support services to aviation, aerospace, and the broader transportation marketplaces.

For additional information on CIES and its products please visit the CIES Inc Website